Filter Results By:

Products

Applications

Manufacturers

Showing results: 1501 - 1515 of 1604 items found.

  • High Frequency RF and Microwave USB Programmable Signal Generators

    LMS Series - Vaunix Technology Corporation

    The Lab Brick LMS series of high frequency RF and microwave USB-compatible, synthesized signal generators cover a frequency range from 0.5 MHz - 20 GHz with low noise, fast 100-microsecond switching time, and fine 100 Hz frequency resolution. They require no additional DC supply voltage and offer advanced features such as phase-continuous linear-frequency sweeping, internal/external 10 MHz reference, and optional pulse modulation. GUI software can track and control several connected signal generators, simplifying multiple-signal test setups. Each device stores settings in internal memory, allowing it to power up in a specific instrument state.

  • Load Cell Amplifier Signal Conditioner with DB9 Connectors

    MODEL LCA-9PC - Transducer Techniques, Inc

    The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.

  • Load Cell Amplifier Signal Conditioner with Removeable Terminals

    MODEL LCA-RTC - Transducer Techniques, Inc

    The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.

  • Gauss Meters

    PCE Instruments

    A gauss meter displays electromagnetic wave measurements in Gauss (G), milliGauss (mG), milliTesla (mT) or microTesla (µT) units. A gauss meter can detect either static (DC) permanent (rare-earth) magnetic or dynamic (AC) electromagnetic fields (EMFs), or both. Thus, it is important to review the specifications of a gauss meter prior to purchase to ensure suitability for the intended application.Neodymium (NdFeB) permanent magnets are among the world's strongest and most widely used magnets. When testing magnets made of neodymium or other rare-earth elements, a gaussmeter or magnetometer capable of measuring DC magnetic fields is required. However, most electromagnetic fields encountered are generated by AC currents. Examples include electrical power lines, transformers and wiring for overhead lighting, solar panels and other electrical devices and equipment. Electromagnetic fields from electrical installations are believed to cause feelings of nervousness, anxiety and paranoia in EMF-sensitive human beings.Most gaussmeters offered by PCE Instruments can be calibrated and certified according to DIN ISO 9000 standards for an additional fee. Replacement gaussmeter probes and optional accessories are available for most gaussmeter models.

  • Rack-Mounted Timing Systems

    CommSync II Family - FEI-Zyfer Inc.

    The CommSync II family of modular systems provide GPS time and frequency outputs to meet your synchronization requirements. All systems include support for multiple input and output modules including 1PPS, IRIG, HAVE QUICK, PTTI, IEEE-1588 PTPv2, low phase noise 1, 5, and 10 MHz sine wave as well as custom outputs.These systems are available with military SAASM MPE-S GB-GRAM, SAASM Force 22E MRU or civilian C/A GPS receivers. Rubidium or OCXO oscillators provide for excellent holdover performance in the event of failure of the reference inputs. In addition, they may be configured as Distribution Time and Frequency (DTF) systems that are synchronized by an external reference. Dual Redundant systems (CommSync II & CommSync II-D) may be configured with two GPS Time & Frequency (GTF) modules and two power supply modules (AC and/or DC power) for redundancy with uninterrupted automatic switchover.

  • 60kw off grid power inverter 110/220V split-phase output converter

    SDP-60KW - Zhejiang Sandi Electric Co., Ltd

    Our SDP series Off Grid Pure sine wave inverter is one of the most advanced DC to AC conversion products in the world, it is suitable use for areas without electricity, vehicles, ships, solar energy, wind turbine and other renewable energy systems and etc, can supply power and provide guarantee effectively for the areas with traffic inconveniences, in the mountains, pastoral, border, island and other areas without electricity. It has the main advantages of high quality sine wave AC output, microcomputer control, humanness design, and it is high efficiency and low no-load loss, and no pollution. The inverter can also supply AC power to all kinds of electric equipment, air conditioners, motors, refrigerators, lights, TV, electric fans and other industrial power supply.1. Using the sixth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It’s service life can up to 15 years or more.2. Intelligentized, modularized, simple structure design with powerful function.3. Two kinds of start mode: Step-down Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter’s usage, which reduced the cost of equipment investment, easy to connect wires and control.4. The output frequency can be setting via LCD panel, it’s very convenient for customer.5. The output voltage can be set between -40 % to +20 % of rated voltage. And the output voltage is very accuracy ±1%.6. The DC input voltage range can be set. Over-voltage point, under-voltage point, over-voltage recovery point, under-voltage recovery point all can be setting via the LCD panel.7. Pure sine wave output. With good dynamic response less than 50MS, waveform distortion rate smaller, higher conversion efficiency and stable output voltage.8. Low Frequency Transformer, which ensures that inverter has high efficiency.9. High conversion efficiency, Max. Efficiency≥94%,if 48VDC input,the efficiency can more than 85%.10. Adopts black pure aluminum radiator, which confirms the best radiating performance.11. Powerful data display function. LCD can display the DC input voltage, output frequency, phase voltage, phase current, AC bypass input voltage, output power KWH, time and date, temperature, fault code display.12. Wide input voltage can be set according to customer’s requirement. Input voltage range can be selected from 150-400V or 300-600V or 400-800V.13. Wide input voltage can work without battery and solar charge controller,save more cost and With MPPT wide voltage input function, maximum use of solar power

  • Nano-ITX SBC With Intel® Atom™ Processor E3845/E3827, LVDS/ VGA/HDMI, Dual LANs And Audio

    NANO840 - Axiomtek Co., Ltd.

    The NANO840 NanoITX board supports Intel® Atom™ processor E3845 or E3827 with one DDR3L 1066/1333 up to 8 GB memory. The NANO840 is capable of operating under wide temperatures from -40°C to +80°C in fanless operation which is designed for working in harsh environments. It comes with multiple display outputs: HDMI, LVDS and VGA with visual experiences enhanced for dual-view supported. Moreover, this small form factor embedded board requires +12V DC power input. The NANO840 is ideal for applications requiring a power-optimized and rich-I/O platform, such as high-end medical imaging, digital signage, kiosks/POI, thin clients, and gaming machines.

  • Calibrator, Calibrated, Current, 185 mm, 78 mm, 38 mm, ± (0.25% FS +1 digit), ± (0.5%FS + 1 digit)

    72-6694 CAL - Tenma

    The 72-6694 CAL from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).

  • Automatic Circuit Breaker Tester

    GDGK-306 - Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd

    1) Test standard: IEC622712) Closing and opening time measurement of 12 channels3) Max difference of closing or opening time measurement of three phases4) C-O and O-C time measurement5) Rated operation sequence test6) Bounce time and frequency measurement of breaker closing7) Circuit breaker closing and opening speed measurement8) Travel-time, Coil current-time curve of circuit breaker operation measurement9) Travel and clearance of circuit breaker measurement10) Variable DC circuit breaker operation power supply11) Closing arc resistance value and connected time measurement12) Closing time and opening time of graphite circuit breaker measurement13) Print test results by internal micro printers

  • Circuit Breaker Tester

    GDGK-307 - Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd

    1) Closing and opening time measurement of 12 channels2) Max difference of closing or opening time measurement of three phases3) C-O and O-C time measurement4) Rated operation sequence test5) Bounce time and frequency measurement of breaker closing6) Circuit breaker closing and opening speed measurement7) Travel-time, coil current-time curve of circuit breaker operation measurement8) Travel and clearance of circuit breaker measurement9) Variable DC circuit breaker operation power supply10) Closing arc resistance value and connected time measurement11) Closing time and opening time of graphite circuit breaker measurement12) Print test results by internal micro printers

  • Portable Digital Storage Oscilloscope

    PDS5022 - Xiamen Lilliput Technology Co., Ltd

    PDS series portable digital storage oscilloscopes embody completely the perfect combination of capability, speed and analysis. With 40-100M bandwidth, 250M S/s realtime sample rate on each and dual channels storage, PDS series would be the ideal instrument for design, maintenance and detection. 250M realtime sample rate for each channelManual Cursor Measurement; 5 automatic measurements; High-speed screen update, Saving 4 Waveforms & setup parameters; plenty of Manual Cursor Measurement, Long memory max 6KBytes/CH,Convenient inserting interface card for RS-232C, Hardcopy and USB; 400V (DC+AV peak) maximum input power; Multilanguage offered for user's convenience Specification

  • Resistance Measurement

    PROMET - KoCoS Messtechnik AG

    High-precision micro-ohm measuring systems with adjustable DC test current for determining resistances on circuit breakers or inductive loads such as transformers, for example. The high-precision ohm meters of the PROMET series are used to determine very low electrical resistances in the µΩ range. The adjustable test current of up to 600 A in combination with a four-wire measuring method delivers measurement results which meet stringent accuracy requirements. State-of-the-art power electronics coupled with a robust design guarantee excellent reliability for use as a portable device in switching stations and industrial environments. Typical applications include determining the contact resistance of switchgear devices and determining the resistance on inductive loads such as transformers.

  • Portable Digital Manometer

    PS309 - Validyne Engineering

    Featured are an integral variable reluctance transducer, solid state electronics module, 3 digit liquid crystal display (LCD)* and battery pack with six 1.5V penlight cells for truly portable operation. The units can also be powered from an external DC power supply or AC battery eliminator (converter) module. The transducer features all corrosion resistant materials in contact with the pressure media (both ports in differential units), very low internal cavity volumes and ultra-low volumetric displacement with full-scale pressure excursion. Transducer calibration is unaffected by dielectric properties of the sensed fluid. Gauge and differential transducers may be disassembled and range changed by simple diaphragm replacement.

  • Natural Cooling Input 380VAC 3 Phase to Output 190-300VDC 10A-40A Rectifier Battery Charger

    SD230D20ZZ - Zhejiang Sandi Electric Co., Ltd

    SANDI “SD” series intelligent high-frequency switch power supply modules are specially developed to meet the demands of modern DC system. The charger rectifiers are designed with world leading patent technology “resonant voltage type soft switching power supply technology”. They feature high efficiency and stability, intelligent control, small size and light weight. Standard RS-485 interface, easy to connect with automation system. “Four remotes” functions, intelligent management. The products are widely used in power plant, substations and etc..Main characteristic of the moduleModularization design, realize N+1 backup;The friendly man-machine interface. Large screen to show, realize man-machine dialogue operate really.RS-485 inrerface, realize “4 remote” function with monitor machine.High efficiency, Nearly 95%-96%;Lightly, 230V/10A natural cooling module only 9kg;Little volume, 230V/10A natural cooling module dimension only 325mm×230mm×130mm;After the full bridge rectifying circuit rectifies 3-phase AC to DC, then adjusted by reactive PFC, power factor>0.94;Function against reverse pour: each module has been added diode against reverse pour at output terminal.LED digital screen, digital calibrate, stable current ,fault alarm Main characteristic of the ModulesThe friendly man-machine interface. LED digital screen, digital calibrate, stable current ,fault alarmHigh efficiency, up to 95%-96%;Light weight, Small sizeAfter the full bridge rectifying circuit rectifies 3-phase AC to DC, then adjusted by reactive PFC, power factor>0.94;Unequal current ratio of parallel connection<+/-3%, can ensure twenty modules work well by parallel connection.Multiple protections including over/under voltage, current limiting, short-circuit, parallel protection, over-temperature protection.Output over-voltage protectionTo prevent the disastrous accident caused by output overvoltage, there is overvoltage protection circuit in the module. Once the output voltage is higher than the threshold, the module locks up automatically and fault indication light is on, the faulty module quits work automatically and doesn’t affect the normal operation of the entire system.Output current limiting protectThe output current cannot increase infinitely. The maximum value of the output current of each module is limited to the rated output current 105%, in this range, the output current value of the module is continuously adjustable. If the load output of the module, the module will play down the output voltage.Output short-circuit protectionWhen short circuit, the output voltage drops to 0 immediately. Limit the short circuit current under 15% of rated output current. The module will not be damaged under short circuit state for a time, and resumes to work automatically after debugging. Module parallel protectionThere is parallel protection circuit in each module to ensure that when the fault module quits the system, the normal work of other modules and the system won’t be effect.Output over-current protectionThe output current cannot increase infinitely. If overloaded, the output voltage decreases automatically to protect the power components. The over current protection can be resumed automatically.

  • Clamp Meters

    Morris Products Inc.

    oltage DC 600V with basic accuracy ±(0.5%+5d)Voltage AC 600V with basic accuracy ±(0.8%+5d)Current AC 400V with basic accuracy ±(2.50%+6d)Slimline Electric Clamp Meter Resistance 20M ohms with basic accuracy ±(1.0%+4d)Continuity buzzer sound at 300 ohmsDiode test current 0.3mA; Open circuit voltage 1.5VAccessories: test leads, carrying case, 2(AAA) 1.5V batteriesSize:8-1/16"L x 2-3/4"W x 1-1/2"HSlimline Electric Clamp Meter Weight: 7oz.2000 LCD display countsDecimal Point ReadingsDisplay with backlightData holdMax holdAuto power offLow battery indication

Get Help